Home >> Mercedes Benz >> 1998 >> C230 >> Repair and Diagnosis >> Accessories & Equipment >> Wiring System (Data Link Connectors, Pwr Dist., Grnd Dist.) >> Electrical System, Equipment & Instructions -- 202 Chassis >> Testing & Repair >> Preparing test without quiescent current retention device - AR54.10-P-1030-02AB

Preparing test without quiescent current retention device - AR54.10-P-1030-02AB

Model 202, 208, 129 

Fig 1: Identifying Electrical Connection Set (201 589 00 99 00)
G04686604
COMMERCIALLY AVAILABLE TOOLS

Number Designation
WH58.30-Z-1001-09A Multimeter

Illustrated on model 202 

  1. Loosen nut on negative pole terminal on battery.

    IMPORTANT Do not remove negative pole terminal!

  2. Prepare multimeter (2) for test using "electrical connection set".
  3. Connect positive (+) test cable to battery ground point (W10).
  4. Switch on multimeter (amps DC).
  5. Carefully pull negative pole terminal on battery up and simultaneously connect negative (-) test cable below the pole terminal on the negative pole (3).
    Fig 2: Identifying Battery Ground Point
    G04686605

    IMPORTANT Do not interrupt circuit when pulling the negative pole terminal upward, because this would erase any faults stored. Completely remove the negative pole terminal only after the multimeter test lead is firmly connected to the negative pole.

  6. Route multimeter (2) with test cable (6) to right out of trunk or cargo area.
  7. Close trunk lid or tailgate.
    Fig 3: Identifying Multimeter & Test Cable Routing
    G04686606