Home >> Mercedes Benz >> 1998 >> C230 >> Repair and Diagnosis >> Accessories & Equipment >> Wiring System (Data Link Connectors, Pwr Dist., Grnd Dist.) >> Electrical System, Equipment & Instructions -- 202 Chassis >> Testing & Repair >> Preparing test with quiescent current retention unit - AR54.10-P-1030-01AC

Preparing test with quiescent current retention unit - AR54.10-P-1030-01AC

Model 210 

Fig 1: Identifying Electrical Connection Set (201 589 00 99 00)
G04633404
Commercially available tools

Number Designation
WH58.30-Z-1001-09A Multimeter
WH58.30-Z-1012-09A Quiescent current retention unit
  1. Open engine hood.
  2. Open cover on positive terminal in left component compartment.
  3. Connect quiescent current retention unit (7) as follows:

    Connect positive lead (+) terminal (4) to jumper starter terminal (c. 30).

    Connect negative lead (-) terminal (5) to engine suspension eye.

    Fig 2: Identifying Quiescent Current Retention Unit, Jumper Starter Terminal And Engine Suspension Eye
    G04633405
  4. Open window in right rear door.
  5. Prepare multimeter (2) for measuring using "Electrical connection set".
  6. Position multimeter test lead (6) through open window in rear door into passenger compartment.
  7. Switch on quiescent current retention unit (7).
    Fig 3: Identifying Multimeter And Test Lead Routing
    G04633406
  8. Remove cover on battery ground pole (W10).
  9. Disconnect negative pole terminal (1) from battery.
  10. Connect multimeter (2) as follows:

    Connect positive (+) test cable to battery ground (W10)

    Connect negative (-) test cable to negative pole (3) on battery.

  11. Close right rear door.
  12. Switch on multimeter (2) (mode amps DC).
  13. Switch off quiescent current retention unit (7), disconnect and remove from engine compartment.
  14. Close engine hood.
    Fig 4: Identifying Battery Ground Cable And Negative Pole Cable
    G04633407