Removing and installing GSM 1800 MHz network compensator - AR82.70-P-0010B
MODEL 210.0 with CODE (854) MB cellular telephone
Fig 1: Identifying GSM 1800 MHz Network Compensator Remove/Install Components - Model 210.0 With Code (854)
| Removal, installation | |||
| 1 | Connect quiescent current retention unit | AR54.10-P-1030-07I | |
| *WH58.30-Z-1012-09A | |||
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury from caustic burns to eyes and skin from battery electrolyte or from handling damaged lead acid batteries. | No fire, sparks, naked flames or smoking. Wear acid-protective gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 2 | Disconnect ground cable of battery | AR54.10-P-0003A | |
| Notes on battery | All models. | AH54.10-P-0001-01A | |
| 3 | Remove side cover on left side of trunk | ||
| 4 | Unscrew welding bolt nut (2) from cradle (1) | ||
| 5 | Unscrew nut (3) from side wall | ||
| 6 | Lift cradle (1) with all control modules out of wheelhouse and place in trunk | ||
| 7.1 | Release connectors on D2B interface for cellular telephone (A59/1) and disconnect | ||
| 7.2 | Release fiber optic cable and disconnect | ||
| 8 | Turn over cradle (1) | ||
| 9 | Release connector on E-network compensator (A28/3) and disconnect | ||
| 10 | Unscrew antenna connections | ||
| 11 | Unscrew bolts (5) | ||
| 12 | Remove E-network compensator (A28/3) | ||
| 13 | Install in the reverse order |
Commercially available tools
| Number | Designation |
|---|---|
| WH58.30-Z-1012-09A | Quiescent current retention unit |