Joint gap dimensions on hoods, doors and lids - RA60001290070X(60-070)
Special tools
NOTE:
Adjust hoods, doors and lids in line with the sketches. The air gap must not be wedge shaped or restricted locally. Deviations from the parallel air gap must be a maximum of 0.5 mm over the whole length. The movable body parts must be centered appropriately in the event of too large or too small a gap in the openings. All intoleranced dimensions ± 0.5 mm. The standard values only apply for repair work on bodywork damaged in accidents.