Disconnecting, connecting engine wiring harness - AR01.00-P-2410H
ENGINE 604, 605, 606 in MODEL 210 as of 1.6.96
| Removal, installation | |||
| 1 | Disconnect ground cable (W10) of battery | AR54.10-P-0003A | |
| 2 | Remove component compartment cover (2) | ||
| 3 | Unplug connector (X22) in the right of the component compartment | ||
| 4 | Unplug connector (A2) at fuse and relay module (K40/4) | ||
| 5 | Unplug connector (A1) at fuse and relay module (K40/4) | ||
| 6 | Separate plug connection of injection pump (Y23/1) at component partition | ||
| 7 | Pull out rubber seal of splash panel and remove cables behind trim panel | ||
| 8 | Disconnect cable of intake air temperature sensor (B17) | ||
| 9 | Unplug connector of glow output stage (N14/2) | ||
| 10 | Disconnect wiring harness (G2) of generator | ||
| 11 | Remove bottom part of noise encapsulation (4) | ||
| 12 | Unbolt terminal block (X4) circuit 30 in left footwell | ||
| 13 | Unbolt engine ground (W11/1) (ground strap) | ||
| 14 | Install in the reverse order |