Repairing wiring harness - AR54.18-P-0100B
MODEL 210
Modification notes
| 16.12.99 | Replaces SI 54/75 from 24.10.95 | Replace 63-pin connector at cable harness. Please remove SI 54/75 from your folder. |
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
| Remove, install connector | |||
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury from caustic burns to eyes and skin from battery electrolyte or from handling damaged lead acid batteries. | No fire, sparks, naked flames or smoking. Wear acid-protective gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 1 | Disconnect battery | ||
| 2 | Remove connector housing cover (A) | ||
| 3 | Release gray secondary lock (2) (Fig 2) | ||
| 4 | Release gray secondary lock (3) (Fig 3) | ||
| 5 | Release 9-pin connector B on underside of connector C (Fig 4) | ||
| 6 | Release 2-pin connector D on underside of connector C (Fig 5) | ||
| N | Inspect connector for damage. | Replace if necessary. |
|
| 8 | Install in the reverse order | ||
| 9 | Check programming of multi-function control module (N10-1) | Program if necessary. |
|
| 10 | Erase fault memory |
Commercially available tools
| Number | Designation |
|---|---|
| WH58.30-Z-1002-32A | Commercially available pressing tools for E95, SPT and MPT contacts |