Convenience closing of tilting/sliding roof function - GF77.20-P-2001A
MODELS 202 as of 1.6.97, 208, 210.081 /281 (except 208.4), 210 (except 210.081 /281) as of 1.3.97
Function prerequisites
- no overvoltage/undervoltage
- circuit 15 off and
- circuit 15R off and
- circuit 15C off detected
Function
The convenience closing function of the tilting/sliding roof is only available in the normalized state . The overhead control panel control module (N70) receives over CAN the request for convenience closing of the tilting/sliding roof and then actuates the tilting/sliding roof motor (M12/1) .
The direction in which the motor is actuated depends on whether the sliding roof or the tilting roof is open.
The motor is actuated until the overhead control panel control module (N70) through the position measurement detects that the tilting/sliding roof is closed.
The function is aborted if
- the request over CAN is no longer received or
- lock-up of the tilting/sliding roof is detected or
- the function requirements listed above are no longer satisfied.
| Power tilting/sliding roof (SR [SHD]) function | GF77.20-P-0001A | ||
| Convenience feature, function | GF80.45-P-0003A | ||
| Close tilting/sliding roof (SR), function | GF77.20-P-2002A | ||
| Tilting/sliding roof (SR) normalization, function | GF77.20-P-3002A | ||
| Sliding/pop-up roof lock-up recognition, function | GF77.20-P-3000A | ||
| Tilting/sliding roof (SR) position measurement, function | GF77.20-P-3001A |