Actuators, testing pneumatics, CL - AD80.20-P-8001-07BA
Pressure range
| Scope of test | Measuring instrument/Test connection | Operation/Requirement | Specified value |
|
|
| 1.0 | Leaktightness in pressure range Note on test connection: Yellow connection on tester | Pressurize actuator to 600 mbar | Pressure drop ≤ 25 mbar in 1 minute |
|