Test values for jacket tube - BE46.10-P-1000-03A
Model 129, 140, 210
Test values for jacket tube
| Number | Designation | Model 129 | Model 140 | Model 210 | |
|---|---|---|---|---|---|
| BE46.10-P-1001-03A | Dimension "a" at top bracket at jacket tube | mm | 21.5+0.5 | 21.5+0.5 | - |
| Fig. see | AR46.10-P-0600-01A | AR46.10-P-0600-01A | - | ||
| BE46.10-P-1002-03A | Jacket tube play at forward/back adjustment motor | mm | 0.25-0.30 | 0.25-0.30 | 0.25-0.30 |
| BE46.10-P-1003-03A | Dimension "b" at top bracket at jacket tube | mm | 30+0.5 | 30+0.5 | 30+0.5 |
| Fig. see | AR46.10-P-0600-01B | AR46.10-P-0600-01B | AR46.10-P-0600-01B | ||