Installing upper bracket for jacket tube - AR46.10-P-0600-01B
TEST VALUES - JACKET TUBE
| Number | Designation | Model 129 | Model 140 | Model 210 | |
|---|---|---|---|---|---|
| BE46.10-P-1003-03A | Dimension "b" on upper bracket on jacket tube | mm | 30+0.5 | 30+0.5 | 30+0.5 |
| Refer to illustration | AR46.10-P-0600-01B | AR46.10-P-0600-01B | AR46.10-P-0600-01B | ||
| Number | Designation | Model 129 | Model 140 | |
|---|---|---|---|---|
| BA46.10-P-1006-03A | Clamping screw of upper bracket on jacket tube | Nm | 5 | 5 |
| Number | Designation | Model 210 | |
|---|---|---|---|
| BA46.10-P-1015-03D | Clamping screw of upper bracket on jacket tube | Nm | 5 |
Installing
- Install bracket (85) at an angle of 90° to jacket tube unit as shown.
- Adjust dimension "b" between bracket (85) and locking ring (70h).
Dimension "b" is determinate for the satisfactory function of the fanfare horns and airbag clock spring contact.
Tighten bolt (85a).