Attaching control cable with adjusting switch - AR46.15-P-0550-06A
- Insert control cable (93c) with adjusting switch (93) at bracket (93d), lock in position in fixing device (93e) and attach at the play adjusters as shown in the illustration.
- Adjust control cable (93c) to the dimension "b" = 11 mm, measured between hydraulic cylinder bracket and hydraulic cylinder lever, using the adjusting nut on the release lever.
- Check adjustment and function again after operating the release lever several times.
The control cable (93c) must only have a slight preload.