Warning Indicator Lamps Completely Inoperative
If indicator lamps are completely inoperative, check the following items and repair as necessary:
- Check wiring. See WIRING DIAGRAMS .
- Check instrument panel voltage supply. Perform TEST 1 under SYSTEM TESTS.
- Check bulbs.
- Check electronic circuit board.