Preparing test with quiescent current retention device - AR54.10-P-1030-01AB
Models 202, 208, 129
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation |
|---|---|
| WH58.30-Z-1001-09A | Multimeter |
| WH58.30-Z-1012-09A | Quiescent current retention unit |
Illustrated on model 202
- Connect quiescent current retention device (7) as follows:
- Connect positive lead terminal (+) to positive pole on battery.
- Connect negative terminal (-) to battery ground (W10).
- Switch on quiescent current retention device (7).
- Disconnect negative pole terminal (1) on battery.
- Connect multimeter (2) as follows using "electrical connection set":
- Connect positive (+) test cable to battery negative lead (1).
- Connect negative (-) test cable to battery negative pole (3).
- Switch on multimeter (2) (amperes range).
- Switch off quiescent current retention device (7) and disconnect.
- Route test cable (6) to right out of trunk or cargo area.
- Close trunk lid.