Notes on Tele Aid emergency call system control module change - AH82.95-P-0001-02A
Model 140 with TELE AID emergency call system
The old TELE AID control module (A35/8) is no longer available for the TELE AID emergency call system
Only the D2B compatible TELE AID control module (A35/8) with D2B connection arrow) is now available as a replacement part. This control module can also be installed on model 140. Then, the D2B connection is not used!
Up to approx. 09.00 it is necessary to erase the programming for the D2B function with DAS (Star diagnosis).
As of approx. 10.00, this function can be accomplished with the HHT.