Stationary heater (STH) diagnosis, fault memory (B1000, B1800, B1801, B1802, B1803, B1810, B1811, B1820, B1821, B1823, B1824) - AD83.70-P-4002A
MODEL 129 as of 1.6.97 with CODE (228) stationary heater
| Stationary heater (STH) diagnosis, advanced information | AD83.70-P-2001A | ||
| Connection and use of test equipment | AD00.00-P-1000AZ | ||
| Connect Hand-Held Tester (HHT) and read out fault memory | AD00.00-P-2000-03A | ||
| Notes on diagnosis with Hand-Held Tester (HHT) on heater booster/stationary heater | AD83.70-P-2001-02A | ||
| Fault memory | |||
| Fault code |
Possible cause | Note | Remedy |
| No fault code | No fault recognized | If there is a complaint nevertheless: ↓ Stationary heater (STH) diagnosis, troubleshooting | AD83.70-P-5001A |
| B 1000 | Stationary heater/heater booster control module (A6n1) defective | Replace stationary heater/heater booster control module (A6n1) | |
| B 1800 | No flame at the start of heater operation nor after automatic repeat start. | See HHT | |
| B 1801 | Flame goes out during heater operation without a new flame after automatic attempt at starting | See HHT | |
| B1801 | Flame goes out more than four times during a heater boost cycle | See HHT | |
| B 1802 Overvoltage |
Operating voltage has exceeded 15.5 V for more than 6 seconds | AD83.70-P-6001-01A | |
| B 1802 Undervoltage |
Operating voltage has been below 10.2 V for more than 20 seconds | AD83.70-P-6001-01A | |
| B 1803 | On flame monitor interrogation, the glow pin (A6r2) in its flame monitor function reports a flame prior to the preglow phase. | Replace glow pin (A6r2) | |
| B 1810 |
Glow pin (A6r2) circuit, short-circuit to positive | AD83.70-P-6001-04A | |
| B 1810 |
Glow pin (A6r2) circuit, open-circuit or short-circuit to ground | AD83.70-P-6001-04B | |
| B 1811 | Malfunction lock-out exists:
or
|
See HHT | |
| B 1820 |
Stationary heater fuel metering pump (Y23) circuit, short-circuit to ground | AD83.70-P-6001-05A | |
| B 1820 |
Stationary heater fuel metering pump (Y23) circuit, open-circuit or short-circuit to positive | AD83.70-P-6001-05B | |
| B 1821 Overload, |
Combustion air blower (A6m2), overload or short-circuit | AD83.70-P-6001-06A | |
| B 1821 |
Combustion air blower (A6m2), open-circuit | AD83.70-P-6001-06B | |
| B 1823 Overload, |
Circulating pump (A6m1), overload or short-circuit | AD83.70-P-6001-07A | |
| B 1823 |
Circulating pump (A6m1), open-circuit | AD83.70-P-6001-07B | |
| B 1824 |
Cable to climate control module, short-circuit to ground | AD83.70-P-6001-08A |