Removing and installing transmitter/receiver unit for infrared interior motion sensor - AR80.50-P-9820EA
MODEL 202 with CODE (882a) Interior motion sensor (infrared)
Fig 1: Identifying Transmitter/Receiver Unit For Infrared Interior Motion Sensor Remove/Install Components
| Removal, installation | |||
|---|---|---|---|
| 1 | Press off cap (7) | ||
| 2 | Pull off door weather-seal in the area of B-pillar | ||
| 3 | Take off B-pillar trim (11) | ||
| 4 | Remove screws (8, 9) at transmitter and receiver unit (A26/4, A26/5) | ||
| 5 | Unplug connector (10) | ||
| 6 | Take off transmitter and receiver unit (A26/4, A26/5) | ||
| 7 | Install in the reverse order | ||
| Perform operational check | dh1303pa20411x Diagnosis Manual Body 13.3 □ 11/1 |
||
| Read fault memory and erase | dh0000pa10003x Diagnosis Manual Body 0 □ 3/1 |