LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 1994 >> C220 >> Repair and Diagnosis >> External Pages >> Different car >> Section 47 (Engine Cooling System - 140 Chassis) >> Testing & Repair >> Checking the shift point of the cooling system - AR20.00-P-1020AO

Checking the shift point of the cooling system - AR20.00-P-1020AO

WARNING: This page does not describe the selected car, but rather 42 other vehicles, including the 1999 Mercedes-Benz S600, 1999 Mercedes-Benz S500, 1999 Mercedes-Benz S420, 1999 Mercedes-Benz S320, and 1999 Mercedes-Benz CL600. However, it is still accessible from the selected car via links, so may be relevant.

engine 120 in MODELS 129, 140 

IMPORTANT Shift points for coolant thermostat   *BE20.10-P-1001-02A 
*BE20.10-P-1002-02A 
*BE20.10-P-1003-02A 
IMPORTANT Shift points for fan clutch, additional fan   *BE20.40-P-1001-01A 
IMPORTANT Shift points for air conditioning   *BE83.00-P-1001-01A 
IMPORTANT Cap switch points   *BE20.30-P-1004-01A 
IMPORTANT Shift points for transmission oil cooling Model 140 *BE27.55-P-1001-01A 
COOLANT THERMOSTAT

Number Designation Engines 103, 104, 111, 120
BE20.10-P-1001-02A Start of opening °C 85...89
BE20.10-P-1002-02A Minimum stroke °C 102
mm 8
BE20.10-P-1003-02A Thermostat bypass valve dia. mm 43
TEST VALUES FOR FAN, FAN CLUTCH

Number Designation Engine 120 in model 129 Engine 120 in model 140
BE20.40-P-1001-01A Shift points for cooling system Viscous fan clutch Shift point for cooling air temperature °C 96±4 96±4
Additional fan cut-in On switch "ON" Km/h 40 -
Cut-in "OFF" km/h 70 -
for outside air temperature °C ≥ 30 -
for outside air temperature "OFF" °C - ≤ 5
for outside air temperature "ON" °C - ≥ 10
for coolant temperature °C 103/95 95/92
for pressure in the refrigerant circuit bar 14/12 14/12
Additional fan fully switched on for coolant temperature °C 115/110 110/107
for pressure in the refrigerant circuit (high pressure side) bar 20/14 20/17
TEST VALUES FOR SWITCH POINTS FOR AIR CONDITIONING

Number Designation Models 129, 140 with engine 120
BE83.00-P-1001-01A Air conditioning Operating time cycles % 50
Cycles "ON" S 20
Cycle "OFF" S 20
Cycle for coolant temperature. °C 123
EMERGENCY STOP °C 127±1
CAP OF RADIATOR OR EXPANSION RESERVOIR

Number Designation 2-stage cap
BE20.30-P-1004-01A Pressure relief valve opens 1st stage bar gage 1.4 (± 1)
Coolant temp. ≥ 130/134
2nd stage bar gage 2.0 (± 1)
Coolant temp. ≥ 137/143
TEST VALUES FOR TRANSMISSION OIL COOLING

Number Designation Transmissions 755.3/6
BE27.55-P-1001-01A Switching temperature E-fan On for transmission oil temperature °C 105
E-fan Off for transmission oil temperature °C 100