Remove contacts from Siemens ELO plug - AR00.19-P-0120-24A
WARNING: This page does not describe the selected car, but rather 42 other vehicles, including the 1999 Mercedes-Benz S600, 1999 Mercedes-Benz S500, 1999 Mercedes-Benz S420, 1999 Mercedes-Benz S320, and 1999 Mercedes-Benz CL600. However, it is still accessible from the selected car via links, so may be relevant.
Secondary release on version with retaining clamp (Siemens ELO)
- Using a suitable tool, pry up the side clips of the retaining clamp (1).
- Move the tabs.
- Detach the retaining bracket (1).
Shown on a 10-pin Siemens ELO plug
Unpin contact pins from the plug (Siemens ELO)
- Position the blade holder with clamping pliers
and MQS blade
on the side of the spring tab of the contact pin (2).
- Press down the spring tab of the contact pin (2), and push the contact pin (2) out of the contact cavity of the connector housing (1). Tug the corresponding cable at the same time to assist the unpinning procedure.
Shown on a 10-pin Siemens ELO plug