Measuring lower wishbone (when removed) - AR40.30-P-0452A
MODEL 129 up to 1.10.93, 140
| Checking | |||
| 1 | Perform visual inspection on wishbone. | Check for corrosion and distortion. | |
| 2 | Push alignment tool, 14 mm dia. length approx. 430 mm, through wishbone bores in the direction of the arrow. | This measurement method can no longer be used on model 129 as of the production breakpoint of the rubber mount with steel sleeve (10/93) ↓. |
|
| Perform visual inspection or comparative check with new part. |