Correcting oil level in air conditioning after system suddenly loses all refrigerant - AR83.30-P-5253C
MODEL 129 with CODE (580) Air conditioning or, for USA, Tempmatic with CODE (581a) Air conditioning (automatic)
A/C compressor 10PA17
| Perform work quickly, compressor oil is hydroscopic When evacuating refrigerant add the quantity of compressor oil removed from the refrigerant circuit when recharging the air conditioner. |
|||
| 1 | Replace defective part and fluid reservoir | with air conditioning or, for USA, Tempmatic code 580 | ra83001290540x |
| with air conditioning/automatic (code 581a) | AR83.30-P-6520C | ||
| 2 | Also add new compressor oil to specified oil quantity | *BF83.55-P-1002-01A | |
| 3 | Switch on air conditioning and allow engine to idle for approx. 4 minutes | Blower to max. |
|
| 4 | Check air conditioning for proper function | replace evaporator temperature sensor (B10/6) |
| Number | Designation | A/C compressor 10PA17 refrigerant R12 in model 129 | A/C compressor 10PA17 refrigerant R134a in model 129 | ||
|---|---|---|---|---|---|
| BF83.55-P-1002-01A | Additional oil quantity when system is suddenly emptied (e.g. line broken) | Compressor oil | cm3 | 40 | 40 |
| Specifications for service products | Page | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||