Limit Switch (S84/6 - Rear Catch/Cloth Holding Brace Up Position): Adjustment
NOTE:
Lay limit switch cable along flexible hydraulic lines.
- Connect multimeter to plug connector (S84/6x). Set multimeter to continuity test (acoustic signal).
- Adjust limit switch (S8416) by moving in oblong holes. Limit switch (S8416) should switch approximately 100 mm before reaching the upper most position of the cloth holding brace.