Home >> Mercedes Benz >> 1992 >> 300SL Automatic >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control -- 129 Chassis >> Self-Diagnostic System >> Stationary heater (STH) diagnosis, fault memory (B1000, B1800, B1801, B1802, B1803, B1810, B1811, B1820, B1821, B1823, B1824) - AD83.70-P-4002A

Stationary heater (STH) diagnosis, fault memory (B1000, B1800, B1801, B1802, B1803, B1810, B1811, B1820, B1821, B1823, B1824) - AD83.70-P-4002A

MODEL 129 as of 1.6.97 with CODE (228) stationary heater 

IMPORTANT Stationary heater (STH) diagnosis, advanced information   AD83.70-P-2001A 
IMPORTANT Connection and use of test equipment   AD00.00-P-1000AZ
IMPORTANT Connect Hand-Held Tester (HHT) and read out fault memory   AD00.00-P-2000-03A
IMPORTANT Notes on diagnosis with Hand-Held Tester (HHT) on heater booster/stationary heater   AD83.70-P-2001-02A 
    IMPORTANT If a fault is displayed, check fuses, cables, plugs and connectors in accordance with the relevant electric wiring diagram for open-circuit and correct connection.  
  Fault memory     
Fault code HAND-HELD TESTER Possible cause  Note  Remedy 
No fault code No fault recognized If there is a complaint nevertheless: ↓ Stationary heater (STH) diagnosis, troubleshooting AD83.70-P-5001A 
B 1000 Stationary heater/heater booster control module (A6n1) defective   Replace stationary heater/heater booster control module (A6n1)
B 1800 No flame at the start of heater operation nor after automatic repeat start.   See HHT
B 1801 Flame goes out during heater operation without a new flame after automatic attempt at starting   See HHT
B1801 Flame goes out more than four times during a heater boost cycle   See HHT
B 1802
Overvoltage
Operating voltage has exceeded 15.5 V for more than 6 seconds   AD83.70-P-6001-01A 
B 1802
Undervoltage
Operating voltage has been below 10.2 V for more than 20 seconds   AD83.70-P-6001-01A 
B 1803 On flame monitor interrogation, the glow pin (A6r2) in its flame monitor function reports a flame prior to the preglow phase.   Replace glow pin (A6r2)
B 1810
SHORT-CIRCUIT TO POSITIVE
Glow pin (A6r2) circuit, short-circuit to positive   AD83.70-P-6001-04A 
B 1810
SHORT-CIRCUIT TO GROUND
Glow pin (A6r2) circuit, open-circuit or short-circuit to ground   AD83.70-P-6001-04B 
B 1811 Malfunction lock-out exists:
  • Thermal fuse in stationary heater/heater booster unit (A6) has blown because the coolant in the heater unit has exceeded the maximum permissible temperature of 125°C

or
  • 3 different or the same faults have occurred in sequence
  See HHT
B 1820
SHORT-CIRCUIT TO GROUND
Stationary heater fuel metering pump (Y23) circuit, short-circuit to ground   AD83.70-P-6001-05A 
B 1820
SHORT-CIRCUIT TO POSITIVE
Stationary heater fuel metering pump (Y23) circuit, open-circuit or short-circuit to positive   AD83.70-P-6001-05B 
B 1821
Overload, SHORT-CIRCUIT
Combustion air blower (A6m2), overload or short-circuit   AD83.70-P-6001-06A 
B 1821
OPEN-CIRCUIT
Combustion air blower (A6m2), open-circuit   AD83.70-P-6001-06B 
B 1823
Overload, SHORT-CIRCUIT
Circulating pump (A6m1), overload or short-circuit   AD83.70-P-6001-07A 
B 1823
OPEN-CIRCUIT
Circulating pump (A6m1), open-circuit   AD83.70-P-6001-07B 
B 1824
SHORT-CIRCUIT TO GROUND
Cable to climate control module, short-circuit to ground   AD83.70-P-6001-08A