Home >> Mercedes Benz >> 1992 >> 300SL Automatic >> Repair and Diagnosis >> Electrical >> Fuses & Circuit Breakers >> Electrical System, Equipment & Instructions -- 129 Chassis >> Testing & Repair >> Checking exterior lamp failure indicator - AR54.30-P-6070CS

Checking exterior lamp failure indicator - AR54.30-P-6070CS

MODEL 129 

Fig 1: Identifying Exterior Lamp Failure Indicator Location
G04686635
INSPECT Inspecting     
REFER TO BASIC KNOWLEDGE Bulb failure indicator light, function   GF54.15-P-1520CS 
1 Switch on lights Visual inspection  
2 Determine defective circuit    
3 Switch off lights IMPORTANT Diagnosis of xenon headlamps, see Diagnosis Manual for Body.  
4 Check bulbs and fuses IMPORTANT Test for vehicles with trailer coupling: ↓
Checking exterior lamp failure indicator
IMPORTANT The lamps are monitored individually by the lamp monitoring unit (N7). In the case of low power (low watt) bulbs, this may be displayed as a fault. No fault is displayed for higher power lamps.
Lamps and fuses OK ↓
Check cables as per wiring diagram for open circuit, short circuit and correct connection. See Wiring Diagrams for model 129
*BE82.10-P-1004-01D 
TEST VALUES FOR EXTERIOR LIGHTS

Number Designation Model 129
BE82.10-P-1004-01D Bulb power ratings Low beam W 55/60
Low beams (Xenon) W -
High beam (with xenon) W H7
Standing / parking lamp W 5
Turn signal lamp/parking lamp USA ONLY W 21/5
Turn signal lamp W 21
Stop lamp W 21
Tail / parking lamp W 21/4
Reversing lamp W 21
License plate illumination W 5
Fog lamp W H1/55
Rear fog lamp W 21