LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 1992 >> 300SL Automatic >> Repair and Diagnosis >> Electrical >> Fuses & Circuit Breakers >> Electrical System, Equipment & Instructions -- 129 Chassis >> Repair & Adjustments >> Adapting fuel consumption display - RA54001070424X(54-424)

Adapting fuel consumption display - RA54001070424X(54-424)

  1. Models 107, 124 and 126 

    If the fuel consumption displayed by the trip computer deviates from the actual consumption, it can be adapted in 2.5% stages by adjusting the microswitches on the trip computer control unit.

    Fig 1: Identifying Trip Computer Control Unit
    G04686682

    Example: - Effective

    consumption: 12.5 l/100 km

    - Trip computer

    consumption display: 11.7 l/100 km

    Error in %= -6.4%

    Consumption correction on microswitches+7.5%.

    Fig 2: Identifying Fuel Consumption Display
    G04686683
  2. Models 129 and 140 

    If the fuel consumption displayed on the trip computer deviates from the actual consumption, it can be adapted in 2.5% stages.

    Setting consumption correction 

    1. Turn key in steering lock to position 2 (terminal 15, engine off).
    2. Hold down clock synchronization button "A" for at least 2 seconds.
      Fig 3: Locating Clock Synchronization Button
      G04686684
      • The tank capacity in liters according to the fuel quantity contained appears in the outside temperature display.
        Fig 4: Identifying Tank Capacity In Liters Display
        G04686685
    3. Pull out clock adjustment knob, turn counterclockwise and release.
      • The stored value is visible in the outside temperature display (factory setting 0%).
        Fig 5: Identifying Outside Temperature Display
        G04686686
    4. Change consumption correction value
      • Pull out clock adjustment knob and turn counter-clockwise.
        Fig 6: Identifying Temperature Display
        G04686687
      • The value changes in stages of 2.5%. The greatest negative value is followed by the greatest positive value until 0% is reached again.
        Fig 7: Identifying Temperature Display
        G04686688

    The adjustment range extends from +25% to -25%.

    Calculating adjustment range

    Example:

    Effective consumption 12.5 l

    Trip computer consumption display 11.7 l

    Error in %=6.4%

    Set next highest correction +7.5.

    NOTE: The values set with the aid of the outside temperature display only become visible on the trip computer display after the test mode of the trip computer has been switched off and on again once.