Removing and installing air cleaner - RA09001040015X(09-0015)
Operation No. of operation texts and work units or standard texts and flat rates:
09 - 0015
| Electrical connector at intake air temperature sensor (B17/2) | disconnect, connect. |
| Air intake hose (2) | at air cleaner, detach, fit on. |
| Nuts (arrows) | unscrew, screw on. |
| Shaped hose (1) | for crankcase ventilation, disconnect, connect. |
| Air cleaner (4) | take off, fit on. |
NOTE:
When installing, ensure rubber seal (7) between air cleaner (4) and mixture control unit is in good condition and properly seated.
Replace rubber seal (7), if necessary.