Hydraulic Unit: Removal
With ignition off, disconnect negative battery cable. Remove hydraulic unit lines, and plug openings. Remove hydraulic unit mounting bolt and cover. Detach pump motor ground strap. Remove 12-pin plug socket. Remove mounting nuts and hydraulic unit.
CAUTION:
DO NOT loosen sealed center bolt or 2 hex socket bolts next to cover and brakelines.