DTC U3000:41 (INSTRUMENT CLUSTER) DIAGNOSTIC PROCEDURE

Step Inspection Action
1 PERFORM DTC INSPECTION AND VERIFY INSTRUMENT CLUSTER MALFUNCTION 
  • Clear the DTC for the instrument cluster using the M-MDS. (See CLEARING DTC .)
  • Retrieve the instrument cluster DTCs using the M-MDS. (See DTC INSPECTION .)
  • Is the same Pending DTC present?
Yes Replace the instrument cluster, then go to the next step.
(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .)
No Go to the next step.
2 VERIFY IF OTHER DTCs DISPLAYED 
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE .)
No DTC troubleshooting completed.