Fuel Siphoning Procedure Using Fuel Pump
WARNING: This page is about a different variant/trim than selected.
NOTE:
- Perform the [Fuel Line Safety Procedure] referring to [BEFORE SERVICE PRECAUTION]. (See BEFORE SERVICE PRECAUTION [PYUL] ).
- Disconnect the quick release connector shown in the figure below. (See QUICK RELEASE CONNECTOR (FUEL SYSTEM) REMOVAL/INSTALLATION [PYUL] ).PART NAME DESCRIPTION
Procedure Part name Applicable condition 1 Quick release connector Continuous Engine oil - Connect the oil-resistant fuel hose connected to the SST to the disconnected quick release connector and collect the gasoline container.SYMBOL AND CONTENT DESCRIPTION
Symbol Content 1 OIL-RESISTANT FUEL HOSE 2 Quick release connector 3 GASOLINE CONTAINER 4 Wiring harness 5 BODY GROUND 6 Fuel pump 7 Fuel tank 49 N013 101A - Connect the wiring harness between the oil-resistant fuel hose and the vehicle body using the following procedure.
- Strip off 10 cm or more of the insulation from both ends of the wiring harness.
- Wrap the on one side around the oil-resistant fuel hose.
- Connect the other end of to a securely grounded part of.
- Operate the fuel pump and drain the fuel according to the following procedure.CAUTION:
- Operating the fuel pump when there is no fuel in the fuel tank may cause a fuel pump malfunction. Verify the amount of fuel discharged from the hose continuously during fuel siphoning, and stop the fuel pump if the discharge amount becomes unstable.
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
- Remove the fuel pump relay.SYMBOL AND CONTENT DESCRIPTION
Symbol Content 1 Fuel pump relay CAUTION:- Shorting the wrong terminal in the relay and fuse block may cause malfunctions. Make sure to short only the specified terminal.
- Short fuel pump relay terminal C and terminal D in the relay and fuse block using a jumper wire.
- Connect the negative battery terminal and operate the fuel pump. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION
.)
- If the fuel pump cannot be operated, remove the fuel using the procedure in the reference. (See FUEL SIPHONING PROCEDURE NOT USING FUEL PUMP )
- Stop the fuel pump by the following procedure.
- Remove the jumper wire and stop the fuel pump.
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)