| 2_WAY_VLV |
OFF/ON |
Select OFF/ON to forcibly drive/stop the expansion valve with solenoid valve (A/C unit side)/expansion valve with solenoid valve (front A/C unit side). |
Expansion valve with solenoid valve (A/C unit side)/expansion valve with solenoid valve (front A/C unit side) |
| 2_WAY_VLV_R |
OFF/ON |
Select OFF/ON to forcibly drive/stop the expansion valve with solenoid valve (rear A/C unit side). |
Expansion valve with solenoid valve (rear A/C unit side) |
| AIR_MIX_MODE_L |
Stopped/AirMix LH Actuator Max Cold Position/AirMix LH Actuator Max Hot Position/AirMix LH Actuator Half Position |
- Stopped: Stops air mix actuator (LH)
- AirMix LH Actuator Max Cold Position: Operates air mix actuator (LH) until air mix door switches to MAX COLD position
- AirMix LH Actuator Max Hot Position: Operates air mix actuator (LH) until air mix door switches to MAX HOT position
- AirMix LH Actuator Half Position: Operates air mix actuator (LH) until air mix door switches to middle position between MAX COLD and MAX HOT positions
|
Air mix actuator (LH) |
| AIR_MIX_MODE_R |
Stopped/AirMix RH Actuator Max Cold Position/AirMix RH Actuator Max Hot Position/AirMix RH Actuator Half Position |
- Stopped: Stops air mix actuator (RH)
- AirMix RH Actuator Max Cold Position: Operates air mix actuator (RH) until air mix door switches to MAX COLD position
- AirMix RH Actuator Max Hot Position: Operates air mix actuator (RH) until air mix door switches to MAX HOT position
- AirMix RH Actuator Half Position: Operates air mix actuator (RH) until air mix door switches to middle position between MAX COLD and MAX HOT positions
|
Air mix actuator (RH) |
| INTAKE_ACTAT_MODE |
Stopped/Intake Actuator Fresh Position/Intake Actuator Recirculation Position/Intake Actuator 25% Rec Position/Intake Actuator 50% Rec Position/Intake Actuator 75% Rec Position |
- Stopped: Stops air intake actuator
- Intake Actuator Fresh Position: Operates air intake actuator until air intake door switches to FRESH position
- Intake Actuator Recirculation Position: Operates air intake actuator until air intake door switches to REC position
- Intake Actuator 25% Rec Position: Operates air intake actuator until air intake door switches to position of REC 25%/FRESH 75%
- Intake Actuator 50% Rec Position: Operates air intake actuator until air intake door switches to position of REC 50%/FRESH 50%
- Intake Actuator 75% Rec Position: Operates air intake actuator until air intake door switches to position of REC 75%/FRESH 25%
|
Air intake actuator |
| MODE_ACTAT_MODE |
Stopped/Mode Actuator Vent Position/Mode Actuator Bi-Level Position/Mode Actuator Heat Position/Mode Actuator Def-Heat Position/Mode Actuator Defroster Position |
- Stopped: Stops airflow mode actuator
- Mode Actuator Vent Position: Operates airflow mode actuator until mode door switches to VENT position
- Mode Actuator Bi-Level Position: Operates airflow mode actuator until mode door switches to Bi-Level position
- Mode Actuator Heat Position: Operates airflow mode actuator until mode door switches to HEAT position
- Mode Actuator Def-Heat Position: Operates airflow mode actuator until mode door switches to DEF/HEAT position
- Mode Actuator Defroster Position: Operates airflow mode actuator until mode door switches to DEFROSTER position
|
Airflow mode actuator |
| R_VENT_ACTAT_MODE |
Stopped/Rear Vent Actuator Vent Position/Rear Vent Actuator Heat Position/Rear Vent Actuator Defroster Position |
- Stopped: Stops rear vent actuator
- Rear Vent Actuator Vent Position: Operates rear vent actuator until rear vent door switches to VENT position
- Rear Vent Actuator Heat Position: Operates rear vent actuator until rear vent door switches to HEAT position
- Rear Vent Actuator Defroster Position: Operates rear vent actuator until rear vent door switches to DEFROSTER position
|
Rear vent actuator |