Clock Spring Inspection [Two-Step Deployment Control System - Us/CANADA Spec.]
- Disconnect the negative battery terminal and wait for 1 min or more. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
- Remove the clock spring. (See CLOCK SPRING REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM - US/CANADA SPEC.] .)
- Verify that the continuity is as indicated in the table.
- If not as indicated in the table, replace the clock spring. (See CLOCK SPRING REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM - US/CANADA SPEC.] .)