Function Inspection Using M-MDS
WARNING: This page is about a different variant/trim than selected.
P0496-00: (PCM - VIN Y) FUNCTION INSPECTION USING M-MDS
| Step |
Inspection |
Results |
Action |
| 1 |
PURPOSE: VERIFY RELATED REPAIR INFORMATION OR SERVICE INFORMATION AVAILABILITY
- Verify related Service Bulletins, on-line repair information, or Service Information availability.
- Is any related Information available?
|
Yes |
Perform repair or diagnosis according to the available information.
- If the vehicle is not repaired, go to the next step.
|
| No |
Go to the next step. |
| 2 |
PURPOSE: RECORD VEHICLE STATUS WHEN DTC WAS DETECTED TO UTILIZE WITH REPEATABILITY VERIFICATION
- Record the freeze frame data/snapshot data and diagnostic monitoring test results (EVAP system related).
NOTE:
- Recording can be facilitated using the screen capture function of the PC.
|
- |
Go to the next step. |
| 3 |
PURPOSE: INSPECTION OF CLOGGING BETWEEN FUEL TANK PRESSURE SENSOR AND FUEL TANK
- Perform the DTC inspection for the PCM. (See DTC INSPECTION
.)
- Are any of the following DTCs displayed?
|
Yes |
The possibility of clogging between fuel tank pressure sensor and fuel tank is high.
- Repair the malfunctioning location according to the applicable DTC troubleshooting. (See P00FE-00:
.)
|
| No |
Go to the next step. |
| 4 |
PURPOSE: VERIFY FUEL TANK PRESSURE SENSOR MEASURED CORRECTLY
- Start the engine and idle it.
- Access the following simulation items using the M-MDS: (see SIMULATION INSPECTION
.)
- PRG_DUTY
- CSTR_VENT_SOL_DUTY
- Change to the following conditions using the simulation function.
- PRG_DUTY: 100 %
- CSTR_VENT_SOL_DUTY: 100 %
- Access the FTP PID using the M-MDS.
- Does the negative pressure change when racing the engine?
|
Yes |
Go to the next step. |
| No |
Go to Troubleshooting Diagnostic Procedure to perform the procedure from Step 1. |
| 5 |
PURPOSE: VERIFY IF ATMOSPHERE BETWEEN CV SOLENOID VALVE AND ATMOSPHERE CAN RELEASE
- Access the following simulation items using the M-MDS: (see SIMULATION INSPECTION
.)
- PRG_DUTY
- CSTR_VENT_SOL_DUTY
- Change to the following conditions using the simulation function.
- PRG_DUTY: 0 %
- CSTR_VENT_SOL_DUTY: 0 %
- Access the EVAP_PRES PID using the M-MDS.
- Is the displayed PID value as follows?
- Approx. 2.6 V (barometric pressure)
|
Yes |
Go to the next step. |
| No |
Go to Troubleshooting Diagnostic Procedure to perform the procedure from Step 2. |
| 6 |
PURPOSE: VERIFY IF PURGE SOLENOID VALVE IS STUCK OPEN
- Access the following simulation items using the M-MDS: (see SIMULATION INSPECTION
.)
- PRG_DUTY
- CSTR_VENT_SOL_DUTY
- Change to the following conditions using the simulation function.
- PRG_DUTY: 0 %
- CSTR_VENT_SOL_DUTY: 100 %
- Access the FTP PID using the M-MDS.
- Is the FTP PID value negative pressure?
|
Yes |
Go to Troubleshooting Diagnostic Procedure to perform the procedure from Step 5. |
| No |
Go to Troubleshooting Diagnostic Procedure to perform the procedure from Step 1. |