DTC P0034-00: Air Bypass Valve Control Circuit Low Input
WARNING: This page is about a different variant/trim than selected.
P0034:00 (PCM - VIN Y) DETECTION CONDITION AND POSSIBLE CAUSE
| System malfunction location |
Air bypass valve control circuit low input |
| Detection condition |
- The air bypass valve control voltage at the PCM terminal 1AX is standard or less relative to the
- PCM control condition.
|
| Fail-safe |
- Stop the supercharging pressure control. (fully open the wastegate valve)
|
| Possible cause |
- Malfunction in wiring harness (including connector/terminal) between main relay and air bypass valve (see CIRCUIT INSPECTION
.) (see CONNECTOR INSPECTION
.)
- Malfunction in wiring harness (including connector/terminal) between air bypass valve and PCM (see CIRCUIT INSPECTION
.) (see CONNECTOR INSPECTION
.)
- Air bypass valve malfunction (Refer to AIR BYPASS VALVE INSPECTION (VIN Y)
in the service information.)
- PCM malfunction (Refer to applicable PCM REMOVAL/INSTALLATION (VIN Y)
in the service information.)
|
| Repeatability verification procedure |
- Clear the DTC recorded in the memory. (see CLEARING DTC
.)
- Perform the KOER self test. (See DTC INSPECTION
.)
|
Courtesy of MAZDA MOTORS CORP.
|
| 1 |
Battery |
| 2 |
Main relay |
| 3 |
Air bypass valve |
| 4 |
PCM |