LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2024 >> 3 Preferred, 4D Hatchback >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Intake Air System And Turbocharger (VIN Y) >> Three Way Solenoid Valve Inspection >> Continuity Inspection

Continuity Inspection

  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  2. Remove the three way solenoid valve. (See THREE WAY SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G 2.5T] .)
  3. Inspect airflow between the ports under the following conditions.
G14579132Courtesy of MAZDA MOTORS CORP.
Measured condition Continuity between nipples A-B Continuity between nipples B-C Continuity between nipples A-C
When voltage is not applied No airflow Airflow detected No airflow
When voltage is applied Airflow detected No airflow No airflow