Microphone inspection
- Launch the diagnostic assist function. (See ACTIVATION PROCEDURE .)
- Select in the following order from the diagnostic assist function initial screen.
- [Functional Inspection/Adjustment]
- [Microphone Inspection]
- Verify if the microphone input status is displayed correctly, or the record and playback function operate correctly.
Microphone inspection screen
-: Not applicable
MICROPHONE INSPECTIONNo. Name Content/function Action 1 Microphone input level The microphone input level is indicated in 8 levels. Inspect the following if the microphone does not operate correctly. - Microphone related DTCs (See DTC TABLE [CMU] .)
- Microphone related symptom troubleshooting (See SYMPTOM TROUBLESHOOTING [ENTERTAINMENT SYSTEM] .)
- Wiring harness between microphone and connectivity master unit (CMU)
2 Record button Record audio input from the microphone for 5 s. 3 Stop button Stop recording or playback. 4 Playback button Playback the recorded audio. 5 - [REC] is indicated while recording. - Ends the diagnostic assist function. (See ENDING PROCEDURE .)NOTE:
- When transitioning from the microphone inspection screen, the recorded audio is cleared.