Diagnostic Procedure
DTC C2006:07 (ELECTRIC PARKING BRAKE CONTROL MODULE) DIAGNOSTIC PROCEDURE
| Step | Inspection | Results | Action |
|---|---|---|---|
| 1 | INSPECT ELECTRIC PARKING BRAKE MOTOR GEAR UNIT (LH) CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 5. | ||
| 2 | INSPECT ELECTRIC PARKING BRAKE CONTROL MODULE CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 5. | ||
| 3 | INSPECT ELECTRIC PARKING BRAKE MOTOR GEAR UNIT (LH) CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
If there is a common connector:
If there is no common connector:
Go to Step 5. |
||
| 4 | VERIFY IF MALFUNCTIONING LOCATION IS ELECTRIC PARKING BRAKE MOTOR GEAR UNIT (LH) DEPENDING ON REPEATABILITY
|
Yes | Replace the electric parking brake motor gear unit (LH), then go to the next step. (See ELECTRIC PARKING BRAKE MOTOR GEAR UNIT REMOVAL/INSTALLATION .) |
| No | Go to Step 6. | ||
| 5 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
Go to the next step. |
| No | Go to the next step. | ||
| 6 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [ELECTRIC PARKING BRAKE CONTROL MODULE] .) |
| No | DTC troubleshooting completed. |