| C101A:00 |
Illuminated |
Illuminated |
Vacuum sensor 1/Vacuum sensor 2 correlation problem |
x |
- |
C, D |
x |
6 |
(See DTC C101A:00 [EVP CONTROL UNIT] .) |
| C101B:16 |
Not illuminated |
Illuminated |
Vacuum sensor 1 circuit low input |
x |
- |
C, D |
x |
4 |
(See DTC C101B:16/C101B:17 [EVP CONTROL UNIT] .) |
| C101B:17 |
Not illuminated |
Illuminated |
Vacuum sensor 1 circuit high input |
x |
- |
C, D |
x |
3 |
| C101B:1C |
Not illuminated |
Illuminated |
Vacuum sensor 1 power supply: low voltage/high voltage |
x |
- |
C, D |
x |
2 |
(See DTC C101B:1C [EVP CONTROL UNIT] .) |
| C101C:00 |
Illuminated |
Illuminated |
Electric vacuum pump: open circuit in drive circuit |
x |
- |
C, D |
x |
3 |
(See DTC C101C:00 [EVP CONTROL UNIT] .) |
| C101C:18 |
Illuminated |
Illuminated |
Electric vacuum pump: drive current decrease |
x |
- |
C, D |
x |
4 |
(See DTC C101C:18 [EVP CONTROL UNIT] .) |
| C101C:71 |
Illuminated |
Illuminated |
Electric vacuum pump: stuck |
x |
- |
C, D |
x |
2 |
(See DTC C101C:71 [EVP CONTROL UNIT] .) |
| C101C:72 |
Illuminated |
Illuminated |
Electric vacuum pump: logic inconsistent |
x |
- |
C, D |
x |
6 |
(See DTC C101C:72 [EVP CONTROL UNIT] .) |
| C101C:73 |
Illuminated |
Illuminated |
Electric vacuum pump: short circuit in drive circuit |
x |
- |
C, D |
x |
2 |
(See DTC C101C:73 [EVP CONTROL UNIT] .) |
| C1035:11 |
Illuminated |
Illuminated |
Electric vacuum pump relay 1: short to ground |
x |
- |
C, D |
x |
3 |
(See DTC C1035:11 [EVP CONTROL UNIT] .) |
| C1035:12 |
Illuminated |
Illuminated |
Electric vacuum pump relay 1: short to power supply |
x |
- |
C, D |
x |
2 |
(See DTC C1035:12 [EVP CONTROL UNIT] .) |
| C1035:13 |
Illuminated |
Illuminated |
Electric vacuum pump relay 1: stuck OFF |
x |
- |
C, D |
x |
2 |
(See DTC C1035:13 [EVP CONTROL UNIT] .) |
| C1036:11 |
Illuminated |
Illuminated |
Electric vacuum pump relay 2: short to ground |
x |
- |
C, D |
x |
3 |
(See DTC C1036:11 [EVP CONTROL UNIT] .) |
| C1036:12 |
Illuminated |
Illuminated |
Electric vacuum pump relay 2: short to power supply |
x |
- |
C, D |
x |
2 |
(See DTC C1036:12 [EVP CONTROL UNIT] .) |
| C1036:13 |
Illuminated |
Illuminated |
Electric vacuum pump relay 2: stuck OFF |
x |
- |
C, D |
x |
3 |
(See DTC C1036:13 [EVP CONTROL UNIT] .) |
| P050F:00 |
Illuminated |
Illuminated |
Low power brake unit vacuum |
- |
- |
C |
x |
6 |
(See DTC P050F:00 [EVP CONTROL UNIT] .) |
| U0001:88 |
Not illuminated |
Illuminated |
CAN communication: module communication error |
x |
- |
C |
x |
8 |
(See DTC U0001:88/U0100:00/U0100:08/U0121:00/U0121:02/U0121:87/U0155:00 [EVP CONTROL UNIT] .) |
| U0100:00 |
Not illuminated |
Illuminated |
CAN communication: communication error to PCM |
x |
- |
C |
x |
8 |
| U0100:08 |
Not illuminated |
Illuminated |
CAN communication: communication error to PCM |
x |
- |
C |
x |
8 |
| U0121:00 |
Not illuminated |
Illuminated |
CAN communication: communication error to DSC HU/CM |
- |
- |
C |
x |
8 |
| U0121:02 |
Not illuminated |
Illuminated |
CAN communication: communication error to DSC HU/CM |
x |
- |
C |
x |
8 |
| U0121:87 |
Not illuminated |
Illuminated |
CAN communication: communication error to DSC HU/CM |
x |
- |
C |
x |
8 |
| U0155:00 |
Not illuminated |
Not illuminated |
CAN communication: communication error to instrument cluster |
- |
- |
C |
x |
8 |
| U0401:00 |
Not illuminated |
Illuminated |
CAN communication: signal error from PCM |
x |
- |
C |
x |
8 |
(See DTC U0401:00/U0401:86 [EVP CONTROL UNIT] .) |
| U0401:86 |
Not illuminated |
Illuminated |
CAN communication: signal error from PCM |
x |
- |
C |
x |
8 |
| U0415:00 |
Not illuminated |
Illuminated |
CAN communication: signal error from DSC HU/CM |
- |
- |
C |
x |
8 |
(See DTC U0415:00/U0415:29/U0415:86 [EVP CONTROL UNIT] .) |
| U0415:29 |
Not illuminated |
Illuminated |
CAN communication: signal error from DSC HU/CM |
x |
- |
C |
x |
8 |
| U0415:86 |
Not illuminated |
Illuminated |
CAN communication: signal error from DSC HU/CM |
x |
- |
C |
x |
8 |
| U3000:11 |
Illuminated |
Illuminated |
EVP control unit internal circuit malfunction |
x |
- |
C, D |
x |
1 |
(See DTC U3000:11/U3000:12/U3000:46/U3000:47/U3000:56/U3000:96 [EVP CONTROL UNIT] .) |
| U3000:12 |
Illuminated |
Illuminated |
EVP control unit internal circuit malfunction |
x |
- |
C, D |
x |
1 |
| U3000:46 |
Illuminated |
Illuminated |
EVP control unit internal circuit malfunction |
x |
- |
C, D |
x |
1 |
| U3000:47 |
Illuminated |
Illuminated |
EVP control unit internal circuit malfunction |
x |
- |
C, D |
x |
1 |
| U3000:4B |
Illuminated |
Illuminated |
EVP control unit: high internal temperature |
x |
- |
C, D |
x |
6 |
(See DTC U3000:4B [EVP CONTROL UNIT] .) |
| U3000:56 |
Illuminated |
Illuminated |
EVP control unit internal circuit malfunction |
x |
- |
C, D |
x |
1 |
(See DTC U3000:11/U3000:12/U3000:46/U3000:47/U3000:56/U3000:96 [EVP CONTROL UNIT] .) |
| U3000:63 |
Illuminated |
Illuminated |
Electric vacuum pump control unit: long period of operation |
x |
- |
C |
x |
7 |
(See DTC U3000:63 [EVP CONTROL UNIT] .) |
| U3000:96 |
Illuminated |
Illuminated |
EVP control unit internal circuit malfunction |
x |
- |
C, D |
x |
1 |
(See DTC U3000:11/U3000:12/U3000:46/U3000:47/U3000:56/U3000:96 [EVP CONTROL UNIT] .) |
| U3003:16 |
Illuminated |
Illuminated |
EVP control unit power supply low input |
x |
- |
C |
x |
5 |
(See DTC U3003:16/U3003:17 [EVP CONTROL UNIT] .) |
| U3003:17 |
Illuminated |
Illuminated |
EVP control unit power supply high input |
x |
- |
C |
x |
5 |