PID/DATA monitor item table
WARNING: This page is about a different variant/trim than selected.
PID/DATA MONITOR PART SPECIFICATION
| Item |
Definition |
Unit |
Condition/Specification |
| VT_IN_ACT |
Actual intake variable valve timing control
- Advance amount from max retard position
|
° (deg) |
- Displays actual intake variable valve timing-advance amount from max retard position Idle (after warm up)
- Approx. 57° Racing (engine speed is 2, 000 rpm)
- Approx. 84°
|
| VT_IN_DES |
Target intake variable valve timing control
- Advance amount from max retard position
|
° (deg) |
- Displays target intake variable valve timing-advance amount from max retard position Idle (after warm up)
- Approx. 0° Racing (engine speed is 2, 000 rpm)
- Approx. 29°
|