DTC Table (Manual A/C)

X: Applicable-: Not applicable

DTC No. Warning/indicator light System malfunction location Fail-safe function Drive cycle Self test type(1) Memory function Refer to
B1086:71 - Airflow mode actuator motor lock x - C x (See DTC B1086:71 (MANUAL A/C) .)
B10FB:71 - Air intake actuator motor lock x - C x (See DTC B10FB:71 (MANUAL A/C) .)
B11F0:12 - Air intake actuator (potentiometer) circuit short to power supply x - C, D x (See DTC B11F0:12, B11F0:13 (MANUAL A/C) 
B11F0:13 - Air intake actuator (potentiometer) circuit open x - C, D x
B11F5:86 - Invalid data (humidity sensor temperature) received from humidity sensor x - C, D x (See DTC B11F5:86, B1A69:86, U210A:86 (MANUAL A/C) .)
B13AA:71 - Air mix actuator motor lock x - C x (See DTC B13AA:71 (MANUAL A/C) 
B13AB:12 - Air mix actuator (potentiometer) circuit short to power supply x - C, D x (See DTC B13AB:12, B13AB:13 (MANUAL A/C) 
B13AB:13 - Air mix actuator (potentiometer) circuit open x - C, D x
B1A69:86 - Invalid data (relative humidity) received from humidity sensor x - C, D x (See DTC B11F5:86, B1A69:86, U210A:86 (MANUAL A/C) .)
B1B71:11 - Evaporator temperature sensor circuit short to ground x - C, D x (See DTC B1B71:11, B1B71:13 (MANUAL A/C) 
B1B71:13 - Evaporator temperature sensor circuit open x - C, D x
B1C1C:12 - Airflow mode actuator (potentiometer) circuit short to power supply x - C, D x (See DTC B1C1C:12, B1C1C:13 [MANUAL AIR CONDITIONER] .)
B1C1C:13 - Airflow mode actuator (potentiometer) circuit open x - C, D x
U0010:88 - Unit communication error (MS-CAN) - - C x (See DTC U0010:88, U0155:00 (MANUAL A/C) 
U0155:00 - Communication error with instrument cluster x - C, D x
U0423:68 - Invalid date received from Instrument cluster x - C, D x (See DTC U0423:68 (MANUAL A/C) .)
U200D:11 - Climate control unit circuit voltage (+5V) circuit short to ground   - C, D x (See DTC U200D:11 (MANUAL A/C) .)
U210A:86 - Invalid data (windshield temperature) received from humidity sensor x - C, D x (See DTC B11F5:86, B1A69:86, U210A:86 (MANUAL A/C) .)
U2300:54 - Configuration error (data not received) x - C, D x (See DTC U2300:54, U2300:55, U2300:56, U2300:64 (MANUAL A/C) .)
U2300:55 - Configuration error (not configured) x - C, D -
U2300:56 - Configuration error (ineffective/no n-interchangeabl e data read) x - C, D x
U2300:64 - Configuration error (error value read) x - C, D x
U3003:16 - Climate control unit power supply circuit voltage below threshold (10 V or less) - - C, D x (See DTC U3003:16, U3003:17 [CLIMATE CONTROL UNIT MANUAL AIR CONDITIONER)] .)
U3003:17 - Climate control unit power supply circuit voltage above threshold (17.3 V or more) - - C, D x
U300E:13 - Climate control unit power supply circuit open (IG2) - - C, D x (See DTC U300E:13 (MANUAL A/C) .)
(1) C: CMDTC self test, D: ODDTC self test