Diagnostic Procedure
WARNING: This page is about a different variant/trim than selected.
TRANSAXLE OVERHEATS (GW6A-EL, GW6AX-EL) DIAGNOSTIC PROCEDURE
| Step | Inspection | Results | Action |
|---|---|---|---|
| 1 | INSPECT SIGNAL PARTS FOR MALFUNCTION
|
Yes | Repair or replace any malfunctioning parts according to the inspection result. |
| No | Go to the next step. | ||
| 2 | INSPECT ATF LEVEL
|
Yes | Adjust the ATF level to the specification. (See AUTOMATIC TRANSAXLE FLUID (ATF) ADJUSTMENT .) |
| No | Go to the next step. | ||
| 3 | VISUALLY INSPECT OIL COOLER
|
Yes | Repair or replace any malfunctioning parts according to the inspection result. (See OIL COOLER REMOVAL/INSTALLATION [GW6A-EL, GW6AX-EL (VIN Y)] .) |
| No | Go to the next step. | ||
| 4 | VERIFY IF MALFUNCTION CAUSE IS CONTROL VALVE BODY
|
Yes | Replace the control valve body. (See CONTROL VALVE BODY REMOVAL/INSTALLATION .) |
| No | Symptom troubleshooting is completed. |