LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2021 >> CX-5 Sport, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 24 (On-Board Diagnostic - Engine Control (VIN Y) (2 Of 3)) >> DTC P0472-00: Exhaust Gas Pressure Sensor Circuit Low Input >> Diagnostic Procedure

Diagnostic Procedure

WARNING: This page is about a different variant/trim than selected.
DTC P0472:00 (PCM, VIN Y) DIAGNOSTIC PROCEDURE

STEP INSPECTION RESULTS ACTION
1 RECORD VEHICLE STATUS AT TIME OF DTC DETECTION TO UTILIZE WITH REPEATABILITY VERIFICATION
NOTE:
  • Recording can be facilitated using the screen capture function of the PC.
  • Record the FREEZE FRAME DATA/snapshot data on the repair order.
- Go to the next step.
2 VERIFY RELATED REPAIR INFORMATION AVAILABILITY
  • Verify related Service Bulletins and/or on-line repair information availability.
  • Is any related repair information available?
Yes Perform repair or diagnosis according to the available repair information.
  • If the vehicle is not repaired, go to the next step.
No Go to the next step.
3 INSPECT EXHAUST GAS PRESSURE SENSOR CONNECTOR CONDITION
  • Switch the ignition off.
  • Disconnect the exhaust gas pressure sensor connector.
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector and/or terminals, then go to Step 9.
No Go to the next step.
4 INSPECT PCM CONNECTOR CONDITION
  • Disconnect the PCM connector.
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector and/or terminals, then go to Step 9.
No Go to the next step.
5 INSPECT EXHAUST GAS PRESSURE SENSOR CIRCUIT FOR SHORT TO GROUND
  • Verify that the exhaust gas pressure sensor and PCM connectors are disconnected.
  • Inspect for continuity between the following terminals (wiring harness-side) and body ground:
    • Exhaust gas pressure sensor terminal A
    • Exhaust gas pressure sensor terminal B
  • Is there continuity?
Yes Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Exhaust gas pressure sensor terminal A-PCM terminal 1BW
  • Exhaust gas pressure sensor terminal B-PCM terminal 1BF

    If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
  • Repair or replace the malfunctioning part.

    If there is no common connector:

  • Repair or replace the wiring harness which has a short to ground.

Go to Step 9.
No Go to the next step.
6 INSPECT EXHAUST GAS PRESSURE SENSOR SIGNAL CIRCUIT AND GROUND CIRCUIT FOR SHORT TO EACH OTHER
  • Verify that the exhaust gas pressure sensor and PCM connectors are disconnected.
  • Inspect for continuity between exhaust gas pressure sensor terminals B and C (wiring harness-side).
  • Is there continuity?
Yes Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Exhaust gas pressure sensor terminal B-PCM terminal 1BF
  • Exhaust gas pressure sensor terminal C-PCM terminal 1BQ

If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to each other.
  • Repair or replace the malfunctioning part.

    If there is no common connector:

  • Repair or replace the wiring harness which has a short to each other.

Go to Step 9.
No Go to the next step.
7 INSPECT EXHAUST GAS PRESSURE SENSOR CIRCUIT FOR OPEN CIRCUIT
  • Verify that the exhaust gas pressure sensor and PCM connectors are disconnected.
  • Inspect for continuity between the following terminals (wiring harness-side):
    • Exhaust gas pressure sensor terminal A-PCM terminal 1BW
    • Exhaust gas pressure sensor terminal B-PCM terminal 1BF
  • Is there continuity?
Yes Go to the next step.
No Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
  • Exhaust gas pressure sensor terminal A-PCM terminal 1BW
  • Exhaust gas pressure sensor terminal B-PCM terminal 1BF

If there is a common connector:
  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
  • Repair or replace the malfunctioning part.

    If there is no common connector:

  • Repair or replace the wiring harness which has an open circuit.

Go to Step 9.
8 INSPECT EXHAUST GAS PRESSURE SENSOR Yes Replace the exhaust gas pressure sensor, then go to the next step.
(See EXHAUST GAS PRESSURE SENSOR REMOVAL/INSTALLATION [VIN Y] .)
No Go to the next step.
9 VERIFY DTC TROUBLESHOOTING COMPLETED
  • Always reconnect all disconnected connectors.
  • Clear the DTC from the PCM memory using the M-MDS. (See CLEARING DTC .)
  • Perform the KOEO or KOER self test. (See KOEO/KOER SELF TEST .)
  • Is the same Pending DTC present?
Yes Repeat the inspection from Step 1.
Go to the next step.
No Go to the next step.
10 VERIFY AFTER REPAIR PROCEDURE Yes Go to the applicable DTC inspection.
(See DTC TABLE .)
No DTC troubleshooting completed.