LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2021 >> CX-30 Turbo Premium >> Repair and Diagnosis >> External Pages >> Different car >> Section 90 (On-Board Diagnostic - Body Control Module (BCM) (3 Of 3)) >> DTC U2608-14: Instrument Cluster Power Supply Circuit Malfunction (BCM) >> Outline

DTC U2608-14: Instrument Cluster Power Supply Circuit Malfunction (BCM): Outline

WARNING: This page is about a different car, the 2020 Mazda CX-30. However, it is still accessible from the selected car via links, so may be relevant.
DTC U2608:14 (BCM) DETECTION CONDITION AND POSSIBLE CAUSE

System malfunction location Instrument cluster power supply circuit malfunction
Detection condition
  • The instrument cluster detects an open circuit or short to ground in the power supply circuit.
Fail-safe Not applicable
Possible cause
  • Instrument cluster connector or terminal malfunction
  • Short to ground or open circuit in instrument cluster power supply circuit
  • Instrument cluster malfunction
  • Body control module (BCM) malfunction
G13559734Courtesy of MAZDA MOTORS CORP.