Diagnostic Procedure
WARNING: This page is about a different car, the 2020 Mazda CX-30. However, it is still accessible from the selected car via links, so may be relevant.
INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS (AUTO A/C) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | PERFORM DASH-ELECTRICAL SUPPLY UNIT DTC INSPECTION
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [DASH-ELECTRICAL SUPPLY UNIT (US)] .) |
| No | Go to the next step. | ||
| 2 | VERIFY BLOWER MOTOR OPERATION
|
Yes | Go to the next step. |
| No | Go to the following malfunction symptom item. (See AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE (AUTO A/C) (US) .) |
||
| 3 | VERIFY AIRFLOW CONDITION
|
Yes | Go to Step 7. |
| No | Go to the next step. | ||
| 4 | VERIFY VENT CONDITION
|
Yes | Open the air vent, then perform the repair completion verification. |
| No | Go to the next step. | ||
| 5 | INSPECT AIR VENT FOR BLOCKAGE
|
Yes | Remove the obstruction, then perform the repair completion verification. |
| No | Go to the next step. | ||
| 6 | VERIFY DUCT INSTALLATION CONDITION
|
Yes | Inspect ducts for restriction, deformity, and air leakage, then perform the repair completion verification. |
| No | Install the incorrectly installed ducts properly, then perform the repair completion verification. (See DASHBOARD DISASSEMBLY/ASSEMBLY [(US)] .) |
||
| 7 | VERIFY AIRFLOW CONDITION
|
Yes | Go to Step 10. |
| No | Go to the next step. | ||
| 8 | INSPECT AIR VENT FOR BLOCKAGE
|
Yes | Remove the obstruction, then perform the repair completion verification. |
| No | Go to the next step. | ||
| 9 | VERIFY DUCT INSTALLATION CONDITION
|
Yes | Inspect ducts for restriction, deformity, and air leakage, then perform the repair completion verification. |
| No | Install the incorrectly installed ducts properly, then perform the repair completion verification. (See FRONT HEAT DUCT REMOVAL/INSTALLATION [(US)] .) (See REAR HEAT DUCT REMOVAL/INSTALLATION [(US)] .) |
||
| 10 | VERIFY AIRFLOW CONDITION
|
Yes | Perform the repair completion verification. |
| No | Go to the next step. | ||
| 11 | INSPECT AIR VENT FOR BLOCKAGE
|
Yes | Remove the obstruction, then perform the repair completion verification. |
| No | Go to the next step. | ||
| 12 | INSPECT AIRFLOW MODE ACTUATOR
|
Yes | Go to the next step. |
| No | Replace the airflow mode actuator, then perform the repair completion verification. (See AIRFLOW MODE ACTUATOR REMOVAL (AUTO A/C) (US) .) (See AIRFLOW MODE ACTUATOR INSTALLATION (AUTO A/C) (US) .) |
||
| 13 | INSPECT AIRFLOW MODE LINK SET OPERATION
|
Yes | Go to the next step. |
| No | Replace the airflow mode link set, or airflow mode door, then perform the repair completion verification. (See A/C UNIT REMOVAL/INSTALLATION [(US)] .) (See A/C UNIT DISASSEMBLY/ASSEMBLY [(US)] .) |
||
| 14 | VERIFY DUCT INSTALLATION CONDITION
|
Yes | Inspect ducts for restriction, deformity, and air leakage, then perform the repair completion verification. |
| No | Install the incorrectly installed ducts properly, then perform the repair completion verification. (See DASHBOARD DISASSEMBLY/ASSEMBLY [(US)] .) |
||
| Repair completion verification | VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
|
Yes | Troubleshooting completed. Explain repairs to customer. |
| No | Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)] .) If the CAN communication is normal, perform the diagnosis from Step 1. |
||