LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2021 >> CX-3 FWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> On-Board Diagnostic - Instrument Cluster >> DTC C1132-41: Malfunction Inside Instrument Cluster (Instrument Cluster) >> Diagnostic Procedure

Diagnostic Procedure

DTC C1132:41 (INSTRUMENT CLUSTER) DIAGNOSTIC PROCEDURE

Step Inspection Action
1 INSPECT ACTIVE DRIVING DISPLAY
Yes Go to the next step.
No Replace the active driving display, then go to the next step.
(See ACTIVE DRIVING DISPLAY REMOVAL/INSTALLATION .)
2 VERIFY THAT REPAIRS HAVE BEEN COMPLETED
Yes Replace the instrument cluster, then go to the next step.
(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .)
No Go to the next step.
3 VERIFY OTHER DTCs
  • Are any other DTCs displayed?
Yes Repair the malfunctioning location according to the applicable DTC troubleshooting.
(See DTC TABLE (INSTRUMENT CLUSTER) .)
No DTC troubleshooting completed.