DTC U0515:68 (INSTRUMENT CLUSTER) DIAGNOSTIC PROCEDURE

Step Inspection Action
1 VERIFY START STOP UNIT DTCs
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE [START STOP UNIT] .)
No Go to the next step.
2 VERIFY IF MALFUNCTIONING LOCATION IS START STOP UNIT DEPENDING ON REPEATABILITY
Yes Replace the start stop unit, then go to the next step.
(See START STOP UNIT REMOVAL/INSTALLATION .)
No Go to Step 4.
3 VERIFY THAT REPAIRS HAVE BEEN COMPLETED
Yes Replace the instrument cluster, then go to the next step.
(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .)
No Go to the next step.
4 VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?
Yes Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
(See DTC TABLE (INSTRUMENT CLUSTER) .)
No DTC troubleshooting completed.