Determination Procedure
CAUTION:
- When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.
- When inspecting the connector, touch it with a paper clip or similar thin pin without directly inserting a tester probe into the terminal.
DETERMINING SHORT TO GROUND LOCATION (CAN-BUS No. 1) (US) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT FOR SHORT TO GROUND BETWEEN BODY CONTROL MODULE (BCM) AND CONNECTOR C-40
|
Yes | Go to the next step. |
| No | Go to Step 3. | ||
| 2 | INSPECT CAN LINE IN BODY CONTROL MODULE (BCM) FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the connector C-40 and body control module (BCM) because the wiring harness is shorted to ground. |
| No | Replace the body control module (BCM) because there is a short to ground in the body control module (BCM). (See BODY CONTROL MODULE (BCM) REMOVAL/INSTALLATION .) |
||
| 3 | INSPECT FOR SHORT TO GROUND BETWEEN EPS CONTROL MODULE AND CONNECTOR C-40
|
Yes | Go to the next step. |
| No | Go to Step 5. | ||
| 4 | INSPECT CAN LINE IN EPS CONTROL MODULE FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the EPS control module and connector C-40 because the wiring harness is shorted to ground. |
| No | Replace the EPS control module because there is a short to ground in the EPS control module. (See STEERING WHEEL AND COLUMN REMOVAL/INSTALLATION (US) .) |
||
| 5 | INSPECT FOR SHORT TO GROUND BETWEEN AFS CONTROL MODULE/AUTO LEVELING CONTROL MODULE AND CONNECTOR C-40
|
Yes | Go to the next step. |
| No | Go to Step 7. | ||
| 6 | INSPECT CAN LINE IN AFS CONTROL MODULE/AUTO LEVELING CONTROL MODULE FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the AFS control module/auto leveling control module and connector C-40 because the wiring harness is shorted to ground. |
| No | Replace the AFS control module/auto leveling control module because there is a short to ground in the AFS control module/auto leveling control module. (See ADAPTIVE FRONT LIGHTING SYSTEM (AFS) CONTROL MODULE REMOVAL/INSTALLATION .) |
||
| 7 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-40 AND CONNECTOR C-13
|
Yes | Repair or replace the wiring harness between the connector C-40 and connector C-13 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 8 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-13 AND CONNECTOR C-21
|
Yes | Repair or replace the wiring harness between the connector C-13 and connector C-21 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 9 | INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTOR C-21
|
Yes | Go to the next step. |
| No | Go to Step 13. | ||
| 10 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-21 AND CONNECTORS C-55, C-56
|
Yes | Repair or replace the wiring harness between the connector C-21 and connectors C-55, C-56 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 11 | INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTORS C-55, C-56
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness between the connectors C-55, C-56 and connector C-21 because the wiring harness is shorted to ground. | ||
| 12 | INSPECT CAN LINE IN SAS CONTROL MODULE FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the SAS control module and connectors C-55, C-56 because the wiring harness is shorted to ground. |
| No | Replace the SAS control module because there is a short to ground in the SAS control module. (See SAS CONTROL MODULE REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM - US/CANADA SPEC.] .) |
||
| 13 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-21 AND CONNECTOR C-07
|
Yes | Repair or replace the wiring harness between the connector C-21 and connector C-07 because the wiring harness is shorted to ground. |
| No |
|
||
| 14 | INSPECT FOR SHORT TO GROUND BETWEEN TCM AND CONNECTOR C-07/CONNECTORS C-37, C-36
|
Yes | Go to Step 17. |
| No | Go to the next step. | ||
| 15 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-02 AND CONNECTOR C-07/CONNECTORS C-37, C-36
|
Yes | Repair or replace the wiring harness between the connector C-02 and connector C-07/connectors C-37, C-36 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 16 | INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the TCM and connector C-02 because the wiring harness is shorted to ground. |
| No | Replace the TCM because there is a short to ground in the TCM. (See CONTROL VALVE BODY REMOVAL/INSTALLATION [GW6AX-EL (US)] .) (See CONTROL VALVE BODY REMOVAL/INSTALLATION [ET6A-EL (US)] .) (See CONTROL VALVE BODY REMOVAL/INSTALLATION [EV6A-EL, EV6AX-EL] .) |
||
| 17 | INSPECT FOR SHORT TO GROUND BETWEEN DSC HU/CM AND CONNECTORS C-37, C-36
|
Yes | Go to the next step. |
| No | Go to Step 19. | ||
| 18 | INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the DSC HU/CM and connectors C-37, C-36 because the wiring harness is shorted to ground. |
| No | Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM. (See DSC HU/CM REMOVAL/INSTALLATION [L.H.D. (US)] .) |
||
| 19 | INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the PCM and connectors C-37, C-36 because the wiring harness is shorted to ground. |
| No | Replace the PCM because there is a short to ground in the PCM. (See PCM REMOVAL/INSTALLATION [(VIN Y) (US)] .) |
||
| 20 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-38 AND TCM
|
Yes | Go to Step 22. |
| No | Go to the next step. | ||
| 21 | INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the TCM and connector C-02 because the wiring harness is shorted to ground. |
| No | Replace the TCM because there is a short to ground in the TCM. See CONTROL VALVE BODY REMOVAL/INSTALLATION [GW6AX-EL (US)]
.) (See CONTROL VALVE BODY REMOVAL/INSTALLATION [ET6A-EL (US)] .) (See CONTROL VALVE BODY REMOVAL/INSTALLATION [EV6A-EL, EV6AX-EL] .) |
||
| 22 | INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the DSC HU/CM and connectors C-37, C-36 because the wiring harness is shorted to ground. |
| No | Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM. (See DSC HU/CM REMOVAL/INSTALLATION [L.H.D. (US)] .) |
||
| 23 | INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the PCM and connector C-07 because the wiring harness is shorted to ground. |
| No | Replace the PCM because there is a short to ground in the PCM. (See PCM REMOVAL/INSTALLATION [(VIN Y) (US)] .) |
||
| 24 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-07 AND CONNECTORS C-37, C-36
|
Yes | Repair or replace the wiring harness between the connector C-07 and connectors C-37, C-36 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 25 | INSPECT FOR SHORT TO GROUND BETWEEN DSC HU/CM AND CONNECTORS C-37, C-36
|
Yes | Go to the next step. |
| No | Go to Step 27. | ||
| 26 | INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the DSC HU/CM and connectors C-37, C-36 because the wiring harness is shorted to ground. |
| No | Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM. (See DSC HU/CM REMOVAL/INSTALLATION [L.H.D. (US)] .) |
||
| 27 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTORS C-37, C-36 AND CONNECTOR C-02
|
Yes | Repair or replace the wiring harness between the connectors C-37, C-36 and connector C-02 because the wiring harness is shorted to ground. |
| No |
|
||
| 28 | INSPECT FOR SHORT TO GROUND BETWEEN DSC HU/CM AND CONNECTOR C-07/CONNECTOR C-02
|
Yes | Go to the next step. |
| No |
|
||
| 29 | INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the DSC HU/CM C-07/connector C-02 because the wiring harness is shorted to ground. |
| No | Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM. (See DSC HU/CM REMOVAL/INSTALLATION [L.H.D. (US)] .) |
||
| 30 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-02 AND CONNECTOR C-38
|
Yes | Repair or replace the wiring harness between the connector C-02 and connector C-38 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 31 | INSPECT FOR SHORT TO GROUND BETWEEN TCM AND CONNECTOR C-38
|
Yes | Go to the next step. |
| No | Go to Step 33. | ||
| 32 | INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the TCM and connector C-38 because the wiring harness is shorted to ground. |
| No | Replace the TCM because there is a short to ground in the TCM. (See CONTROL VALVE BODY REMOVAL/INSTALLATION [GW6AX-EL (US)] .) (See CONTROL VALVE BODY REMOVAL/INSTALLATION [ET6A-EL (US)] .) (See CONTROL VALVE BODY REMOVAL/INSTALLATION [EV6A-EL, EV6AX-EL] .) |
||
| 33 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-38 AND CONNECTOR C-01
|
Yes | Repair or replace the wiring harness between the connector C-38 and connector C-01 because the wiring harness is shorted to ground. |
| No | Go to Step 35. | ||
| 34 | INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-02 AND CONNECTOR C-01
|
Yes | Repair or replace the wiring harness between the connector C-02 and connector C-01 because the wiring harness is shorted to ground. |
| No | Go to the next step. | ||
| 35 | INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness between the PCM and connector C-01 because the wiring harness is shorted to ground. |
| No | Replace the PCM because there is a short to ground in the PCM. (See PCM REMOVAL/INSTALLATION [(VIN 7 & VIN L) (US)]
.) (See PCM REMOVAL/INSTALLATION [(VIN M) (US)] .) |
||