LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2018 >> CX-9 Touring, AWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> On-Board Diagnostic - Instrument Cluster >> DTC U2100-00: Instrument Cluster Configuration Error >> Notes

DTC U2100-00: Instrument Cluster Configuration Error: Notes

DTC U2100:00 (INSTRUMENT CLUSTER) DETECTION CONDITION AND POSSIBLE CAUSE

Description Instrument Cluster Configuration Error
Detection Condition
  • Instrument cluster configuration error detected as follows:
    • No configuration of instrument cluster
      • Instrument cluster configuration has not been correctly performed.
Fail-safe Function Not applicable
Possible Cause
  • Instrument cluster configuration error
  • Instrument cluster malfunction
System Wiring Diagram Not applicable