| B1086:71 |
- |
Airflow mode actuator motor lock |
X |
- |
C |
X |
(See DTC B1086:71 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| B10FB:71 |
- |
Air intake actuator motor lock |
X |
- |
C |
X |
(See DTC B10FB:71 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| B11F0:12 |
- |
Air intake actuator (potentiometer) circuit short to power supply |
X |
- |
C, D |
X |
(See DTC B11F0:12, B11F0:13 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| B11F0:13 |
- |
Air intake actuator (potentiometer) circuit open |
X |
- |
C, D |
X |
| B11F5:86 |
- |
Invalid data (humidity sensor temperature) received from humidity sensor |
X |
- |
C, D |
X |
(See DTC B11F5:86, B1A69:86, U210A:86 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| B13AA:71 |
- |
Air mix actuator motor lock |
X |
- |
C |
X |
(See DTC B13AA:71 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| B13AB:12 |
- |
Air mix actuator (potentiometer) circuit short to power supply |
X |
- |
C, D |
X |
(See DTC B13AB:12, B13AB:13 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| B13AB:13 |
- |
Air mix actuator (potentiometer) circuit open |
X |
- |
C, D |
X |
| B1A69:86 |
- |
Invalid data (relative humidity) received from humidity sensor |
X |
- |
C, D |
X |
(See DTC B11F5:86, B1A69:86, U210A:86 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| B1B71:11 |
- |
Evaporator temperature sensor circuit short to ground |
X |
- |
C, D |
X |
(See DTC B1B71:11, B1B71:13 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| B1B71:13 |
- |
Evaporator temperature sensor circuit open |
X |
- |
C, D |
X |
| B1C1C:12 |
- |
Airflow mode actuator (potentiometer) circuit short to power supply |
X |
- |
C, D |
X |
(See DTC B1C1C:12, B1C1C:13 [MANUAL AIR CONDITIONER] .) |
| B1C1C:13 |
- |
Airflow mode actuator (potentiometer) circuit open |
X |
- |
C, D |
X |
| U0010:88 |
- |
Unit communication error (MS-CAN) |
- |
- |
C |
X |
(See DTC U0010:88, U0155:00 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| U0155:00 |
- |
Communication error with instrument cluster |
X |
- |
C, D |
X |
| U0423:68 |
- |
Invalid date received from Instrument cluster |
X |
- |
C, D |
X |
(See DTC U0423:68 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| U200D:11 |
- |
Climate control unit circuit voltage (+5V) circuit short to ground |
- |
- |
C, D |
X |
(See DTC U200D:11 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| U210A:86 |
- |
Invalid data (windshield temperature) received from humidity sensor |
X |
- |
C, D |
X |
(See DTC B11F5:86, B1A69:86, U210A:86 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| U2300:54 |
- |
Configuration error (data not received) |
X |
- |
C, D |
X |
(See DTC U2300:54, U2300:55, U2300:56, U2300:64 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| U2300:55 |
- |
Configuration error (not configured) |
X |
- |
C, D |
- |
| U2300:56 |
- |
Configuration error (ineffective/no n-interchangeable data read) |
X |
- |
C, D |
X |
| U2300:64 |
- |
Configuration error (error value read) |
X |
- |
C, D |
X |
| U3003:16 |
- |
Climate control unit power supply circuit voltage below threshold (10 V or less) |
- |
- |
C, D |
X |
(See DTC U3003:16, U3003:17 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |
| U3003:17 |
- |
Climate control unit power supply circuit voltage above threshold (17.3 V or more) |
- |
- |
C, D |
X |
| U300E:13 |
- |
Climate control unit power supply circuit open (IG2) |
- |
- |
C, D |
X |
(See DTC U300E:13 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] .) |