LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-5 Grand Select, FWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> On-Board Diagnostic - Manual A/C >> DTC B1C1C-12; B1C1C-13; Airflow Mode Actuator (Potentiometer) Circuit Short To Power Supply Or Open >> Notes

DTC B1C1C-12; B1C1C-13; Airflow Mode Actuator (Potentiometer) Circuit Short To Power Supply Or Open: Notes

DTC DETECTION DESCRIPTIONA

System malfunction location
  • B1C1C:12: Airflow mode actuator (potentiometer) circuit short to power supply
  • B1C1C:13: Airflow mode actuator (potentiometer) circuit open
Detection condition
  • Malfunction in wiring harness between airflow mode actuator and climate control unit
Fail-safe function Malfunction determined when ignition switched ON
  • Airflow mode actuator drive signal is stopped right when the malfunction is determined.

    Malfunction already exists when ignition switched ON

  • Control based on ambient temperature.
Possible cause
  • Connector or terminal malfunction
  • Airflow mode actuator malfunction
  • Open circuit in wiring harness between the following terminals:
    • Climate control unit terminal L-airflow mode actuator terminal B
    • Climate control unit terminal K-airflow mode actuator terminal C
      • Climate control unit terminal R-airflow mode actuator terminal A
  • Short to power supply in wiring harness between the following terminals:
    • Climate control unit terminal L-airflow mode actuator terminal B
    • Climate control unit terminal K-airflow mode actuator terminal C
      • Climate control unit terminal R-airflow mode actuator terminal A
  • Climate control unit malfunction
G11431963