LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-5 Grand Select, FWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> On-Board Diagnostic - Auto A/C >> DTC B1C1C-12; B1C1C-13; Airflow Mode Actuator (Potentiometer) Circuit Short To Power Supply Or Circuit Open >> Notes

DTC B1C1C-12; B1C1C-13; Airflow Mode Actuator (Potentiometer) Circuit Short To Power Supply Or Circuit Open: Notes

DTC DETECTION DESCRIPTION

System malfunction location
  • B1C1C:12: Airflow mode actuator (potentiometer) circuit short to power supply
  • B1C1C:13: Airflow mode actuator (potentiometer) circuit open
Detection condition
  • Malfunction in wiring harness between airflow mode actuator and climate control unit
Fail-safe function Malfunction determined when ignition switched ON
  • Airflow mode actuator drive signal is stopped right when the malfunction is determined.
    • However, for manual operation using the MODE switch, only vent mode is available.
      • Defroster switch operation is available.

Malfunction already exists when ignition switched ON
  • Control based on ambient temperature.
    • However, for manual operation using the MODE switch, only vent mode is available.
      • Defroster switch operation is available.
Possible cause
  • Connector or terminal malfunction
  • Airflow mode actuator malfunction
  • Open circuit in wiring harness between the following terminals:
    • Climate control unit terminal 1C-airflow mode actuator terminal B
    • Climate control unit terminal 1B-airflow mode actuator terminal C
      • Climate control unit terminal 1Q-airflow mode actuator terminal A
  • Short to power supply in wiring harness between the following terminals:
    • Climate control unit terminal 1C-airflow mode actuator terminal B
    • Climate control unit terminal 1B-airflow mode actuator terminal C
      • Climate control unit terminal 1Q-airflow mode actuator terminal A
  • Climate control unit malfunction
G11431947