DTC B1C1C-12; B1C1C-13; Airflow Mode Actuator (Potentiometer) Circuit Short To Power Supply Or Circuit Open: Notes
DTC DETECTION DESCRIPTION
| System malfunction location |
- B1C1C:12: Airflow mode actuator (potentiometer) circuit short to power supply
- B1C1C:13: Airflow mode actuator (potentiometer) circuit open
|
| Detection condition |
- Malfunction in wiring harness between airflow mode actuator and climate control unit
|
| Fail-safe function |
Malfunction determined when ignition switched ON
- Airflow mode actuator drive signal is stopped right when the malfunction is determined.
- However, for manual operation using the MODE switch, only vent mode is available.
- Defroster switch operation is available.
Malfunction already exists when ignition switched ON
- Control based on ambient temperature.
- However, for manual operation using the MODE switch, only vent mode is available.
- Defroster switch operation is available.
|
| Possible cause |
- Connector or terminal malfunction
- Airflow mode actuator malfunction
- Open circuit in wiring harness between the following terminals:
- Climate control unit terminal 1C-airflow mode actuator terminal B
- Climate control unit terminal 1B-airflow mode actuator terminal C
- Climate control unit terminal 1Q-airflow mode actuator terminal A
- Short to power supply in wiring harness between the following terminals:
- Climate control unit terminal 1C-airflow mode actuator terminal B
- Climate control unit terminal 1B-airflow mode actuator terminal C
- Climate control unit terminal 1Q-airflow mode actuator terminal A
- Climate control unit malfunction
|
|
|