LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-5 Grand Select, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 93 (Charging System - I-ELOOP) >> GENERATOR INSPECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITH i-ELOOP)] >> Generator Internal Parts >> Rectifier (Using an analog circuit tester)

Rectifier (Using an analog circuit tester)

WARNING: This page is about a different car, the 2017 Mazda 3. However, it is still accessible from the selected car via links, so may be relevant.
  1. Inspect for continuity of the diodes using an analog circuit tester.
    Fig 1: Checking For Continuity Of Diodes Using Analog Circuit Tester
    G09782838Courtesy of MAZDA MOTORS CORP.
    • If not as specified, replace the rectifier.
SPECIFICATION WITH CONTINUITY STATUS OF DIODES

Negative Positive Continuity
E P1, P2, P3, P4, P5, P6 Yes
B No
P1, P2, P3, P4, P5, P6 E No
B Yes